Aqua Logic AQL-PS-4 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Accessoires pour piscines hors sol Aqua Logic AQL-PS-4. Aqua Logic AQL-PS-4 User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 44
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Aqua Logic Programming Flow Chart
Aqua LogicAqua Logic
Aqua LogicAqua Logic
Aqua Logic
Automation and Chlorination
Installation Manual
for models
AQL-PS-4 AQL-PS-8-V
AQL-PS-8 AQL-PS-16-V
AQL-PS-16
www.goldlinecontrols.com
888-921-7665
092042H
Copyright © 2008 Goldine Controls
(actuators, cell & remote display not included - order separately)
North Kingstown, RI 02852 USA
denotes conditional items
PS-4 only
PS-4 only
LD
C
G
LINE
ON
T
ROLS
LD
C
G
LINE
ON
T
ROLS
Vue de la page 0
1 2 3 4 5 6 ... 43 44

Résumé du contenu

Page 1 - Aqua Logic

Aqua Logic Programming Flow ChartAqua LogicAqua LogicAqua LogicAqua LogicAqua LogicAutomation and ChlorinationInstallation Manualfor modelsAQL-PS-4 AQ

Page 2 - IMPORTANT SAFETY INSTRUCTIONS

Wired Remote ControlsUp to 3 wired remote controls can be installed. See “Electrical Wiring” (page 19) for instructions onrunning the cable from the

Page 3 - Interference

Optional Base StationThe optional base station, Goldline part number AQL-BASE-RF or AQL2-BASE-RF, must be installedif any wireless remote control is u

Page 4 - Introduction

3. Plumbing“Standard” Pool/Spa system configurationThese systems use a single filter pump and filter. Pool or spa operation is controlled by two 3-wa

Page 5

“Dual Equipment - Separate Heaters” for Pool/Spa configurationThese systems have 2 complete sets of equipment (filter pump, filter, heater)—1 set for

Page 6

3. The solar sensor should be installed on the spa loop prior to the heater and will display the spatemperature whenever the “Spa Filter” pump is runn

Page 7

2. The water sensor should be installed on the pool loop prior to the heater(s) and will display thepool temperature whenever the “Pool Filter” pump i

Page 8

4. Electrical WiringThe Aqua Logic Control Center and PS-16 Expansion Unit require both high and low voltage connec-tions. Low voltage connections w

Page 9

General Purpose OutletIf desired, a duplex receptacle with weatherproof cover (supplied by installer) may be installed in theknockouts on the lower ri

Page 10 - Wireless Remote Controls

Two speed filter pump: Requires 2 relays (FILTER plus one of the AUX relays) for proper operation ofboth speeds. !IMPORTANT: Be sure to follow the

Page 11 - Optional Valve Actuators

The manuals supplied with most heaters also include specific wiring instructions for connecting the heaterto an external control (usually identified a

Page 12 - 3. Plumbing

IMPORTANT SAFETY INSTRUCTIONSWhen using this electrical equipment, basic safety precautions should always befollowed, including the following:•READ AN

Page 13 - Pool and Spa-Dual

Hayward HeatersRefer to the instructions in the heater manual for “2-wire Remote Thermostat” operation under “RemoteControl Connections” and the diagr

Page 14

Raypak RP2100 Pool/Spa Heater1. Turn power off to heater.2. Push the mode button to “spa” mode.3. Set the temperature to the maximum.4. Push the m

Page 15 - Flow switch after cell

Base StationPlug in the pigtail connector from the wireless base station into the “wireless” connector on the main PCBin the Aqua Logic control unit.P

Page 16 - 4. Electrical Wiring

Base StationPlug in the pigtail connector from the wireless base station into the “wireless” connector on the main PCBin the Aqua Logic control unit.P

Page 17 - Aqua Logic Control Power

Raypak RP2100 Pool/Spa Heater1. Turn power off to heater.2. Push the mode button to “spa” mode.3. Set the temperature to the maximum.4. Push the m

Page 18 - Configuration Menus

Hayward HeatersRefer to the instructions in the heater manual for “2-wire Remote Thermostat” operation under “RemoteControl Connections” and the diagr

Page 19 - PS-8 and PS-16 Virtual Models

The manuals supplied with most heaters also include specific wiring instructions for connecting the heaterto an external control (usually identified a

Page 20 - Group Function

Two speed filter pump: Requires 2 relays (FILTER plus one of the AUX relays) for proper operation ofboth speeds. !IMPORTANT: Be sure to follow the

Page 21 - STA-RITE Heater

General Purpose OutletIf desired, a duplex receptacle with weatherproof cover (supplied by installer) may be installed in theknockouts on the lower ri

Page 22 - 500 ft max

4. Electrical WiringThe Aqua Logic Control Center and PS-16 Expansion Unit require both high and low voltage connec-tions. Low voltage connections w

Page 23

Table of ContentsIntroduction Before You Begin... 1Installation Steps...

Page 24

2. The water sensor should be installed on the pool loop prior to the heater(s) and will display thepool temperature whenever the “Pool Filter” pump i

Page 25

3. The solar sensor should be installed on the spa loop prior to the heater and will display the spatemperature whenever the “Spa Filter” pump is runn

Page 26

“Dual Equipment - Separate Heaters” for Pool/Spa configurationThese systems have 2 complete sets of equipment (filter pump, filter, heater)—1 set for

Page 27

3. Plumbing“Standard” Pool/Spa system configurationThese systems use a single filter pump and filter. Pool or spa operation is controlled by two 3-wa

Page 28

Optional Base StationThe optional base station, Goldline part number AQL-BASE-RF or AQL2-BASE-RF, must be installedif any wireless remote control is u

Page 29

Wired Remote ControlsUp to 3 wired remote controls can be installed. See “Electrical Wiring” (page 19) for instructions onrunning the cable from the

Page 30

2. Mounting the EquipmentAqua Logic Control CenterThe Aqua Logic is contained in a raintight enclosure that is suitable for outdoor mounting. The co

Page 31

Pool Sizing FormulaType of Salt to UseIt is important to use only sodium chloride (NaCl) salt

Page 32

Gallons and (Liters) of Pool/Spa water12,000 14,000 16,00018,00020,00022,00032,00024,00034,00026,00036,00028,00038,00030,00040,000Current salt level(4

Page 33

ºC ºF TiCalcuimHardnessCiTot alAlkalinityAi53606676849410312161924293439.3.4.5.6.7.8.9How to use: Measure pool pH, temperature, calcium h

Page 34

IntroductionBefore You BeginWhat’s IncludedBefore attempting to install the Aqua Logic system, check that the following components have beenincluded i

Page 35

NOTE: Before installing this product as part of a saline water purification system in a pool or spa usingnatural stone for coping or for immediately a

Page 36 - 2. Mounting the Equipment

IntroductionBefore You BeginWhat’s IncludedBefore attempting to install the Aqua Logic system, check that the following components have beenincluded i

Page 37 - Gallons

Table of ContentsIntroduction Before You Begin... 1Installation Steps...

Page 38 - Salt Level

IMPORTANT SAFETY INSTRUCTIONSWhen using this electrical equipment, basic safety precautions should always befollowed, including the following:•READ AN

Page 39 - 1. Preparing Pool/Spa Water

Aqua Logic Programming Flow ChartAqua LogicAqua LogicAqua LogicAqua LogicAqua LogicAutomation and ChlorinationInstallation Manualfor modelsAQL-PS-4 AQ

Page 40 - Program Automatic Operation

NOTE: Before installing this product as part of a saline water purification system in a pool or spa usingnatural stone for coping or for immediately a

Page 41

ºC ºF TiCalcuimHardnessCiTot alAlkalinityAi53606676849410312161924293439.3.4.5.6.7.8.9How to use: Measure pool pH, temperature, calcium h

Page 42

Gallons and (Liters) of Pool/Spa water12,000 14,000 16,00018,00020,00022,00032,00024,00034,00026,00036,00028,00038,00030,00040,000Current salt level(4

Page 43

Pool Sizing FormulaType of Salt to UseIt is important to use only sodium chloride (NaCl) salt

Page 44

2. Mounting the EquipmentAqua Logic Control CenterThe Aqua Logic is contained in a raintight enclosure that is suitable for outdoor mounting. The co

Commentaires sur ces manuels

Pas de commentaire